 19-2838; Rev 0; 4/03
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
General Description
The MAX1253/MAX1254 are stand-alone, 10-channel (8 external, 2 internal) 12-bit system monitor ADCs with internal reference. A programmable single-ended/differential mux accepts voltage and remote-diode temperature-sensor inputs. These devices independently monitor the input channels without microprocessor interaction and generate an interrupt when any variable exceeds user-defined limits. The MAX1253/MAX1254 configure both high and low limits, as well as the number of fault cycles allowed, before generating an interrupt. These ADCs can also perform recursive data averaging for noise reduction. Programmable wait intervals between conversion sequences allow the selection of the sample rate. At the maximum sampling rate of 94ksps (auto mode, single channel enabled), the MAX1253 consumes only 5mW (1.7mA at 3V). AutoShutdownTM reduces supply current to 190A at 2ksps and to less than 8A at 50sps. Stand-alone operation, combined with ease of use in a small package (16-pin TSSOP), makes the MAX1253/ MAX1254 ideal for multichannel system-monitoring applications. Low power consumption also makes these devices a good fit for hand-held and battery-powered applications.
Features
o Monitor 10 Signals Without Processor Intervention o Eight External Channels Programmable as Temperature or Voltage Monitors o Intelligent Circuitry for Reliable Autonomous Measurement Programmable Digital Averaging Filter Programmable Fault Counter o Precision Measurements 12-Bit Resolution 1 LSB INL, 1 LSB DNL 0.75C Temperature Accuracy (typ) o Flexible Automatic Channel Scan Sequencer with Programmable Intervals Programmable Inputs: Single Ended/Differential, Voltage/Temperature Programmable Wait State o Internal 2.5V/4.096V Reference (MAX1253/MAX1254) o Remote Temperature Sensing Up to 10m (Differential Mode) o Single 3V or 5V Supply Operation o Small 16-Pin TSSOP Package
MAX1253/MAX1254
Applications
System Supervision Remote Telecom Networks Server Farms Remote Data Loggers
PART MAX1253AEUE* MAX1253BEUE MAX1254AEUE* MAX1254BEUE
Ordering Information
TEMP RANGE -40C to +85C -40C to +85C -40C to +85C -40C to +85C PIN-PACKAGE 16 TSSOP 16 TSSOP 16 TSSOP 16 TSSOP
*Future product--contact factory for availability.
Selector Guide
PART MAX1253AEUE* MAX1253BEUE MAX1254AEUE* MAX1254BEUE INL (LSB) 1 1 1 1 TEMP ERROR (C) 1.0 3.0 1.0 2.5 SUPPLY VOLTAGE (V) 2.7 to 3.6 2.7 to 3.6 4.5 to 5.5 4.5 to 5.5
Pin Configuration
TOP VIEW
AIN0 1 AIN1 2 AIN2 3 AIN3 4 AIN4 5 AIN5 6 AIN6 7 16 CS 15 SCLK 14 DIN
MAX1253 MAX1254
13 VDD 12 GND 11 DOUT 10 INT 9 REF
*Future product--contact factory for availability.
Typical Application Circuit appears at end of data sheet. AutoShutdown is a trademark of Maxim Integrated Products, Inc.
AIN7 8
16 TSSOP 1
________________________________________________________________ Maxim Integrated Products
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim's website at www.maxim-ic.com.
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
ABSOLUTE MAXIMUM RATINGS
VDD to GND .............................................................-0.3V to +6V Analog Inputs to GND (AIN0-AIN7, REF) ... -0.3V to (VDD + 0.3V) Digital Inputs to GND (DIN, SCLK, CS) .... -0.3V to (VDD + 0.3V) Digital Outputs to GND (DOUT, INT) ........ -0.3V to (VDD + 0.3V) Digital Outputs Sink Current ............................................. 25mA Maximum Current into Any Pin .......................................... 50mA Continuous Power Dissipation (TA = +70C) 16-Pin TSSOP (derate 8.7mW/C above +70C) .........696mW Operating Temperature Range ...........................-40C to +85C Junction Temperature ......................................................+150C Storage Temperature Range .............................-65C to +150C Lead Temperature (soldering, 10s) .................................+300C
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VDD = +2.7V to +3.6V (MAX1253), VDD = +4.5V to +5.5V (MAX1254), VREF = +2.5V (MAX1253), VREF = +4.096V (MAX1254), fSCLK = 10MHz (50% duty cycle), TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25C.)
PARAMETER DC ACCURACY Resolution Integral Nonlinearity (Note 1) Differential Nonlinearity Offset Error Gain Error (Note 2) Offset Error Tempco Gain and Temperature Coefficient Channel-to-Channel Offset Matching VDD Monitor Accuracy Internal reference External reference Internal reference External reference Internal reference 5 2 30 0.1 2.5 RES INL DNL Grade A Grade B No missing codes overtemperature 12 1.0 1.0 1.0 4.0 4.0 2.0 Bits LSB LSB LSB LSB %FSR ppm/C ppm/C LSB % SYMBOL CONDITIONS MIN TYP MAX UNITS
DYNAMIC ACCURACY (10kHz sine-wave input, 2.5VP-P (MAX1253), 4.096VP-P (MAX1254), 64ksps, fSCLK = 10MHz, bipolar input mode) Signal-to-Noise Plus Distortion Total Harmonic Distortion Spurious-Free Dynamic Range Full-Power Bandwidth Full Linear Bandwidth CONVERSION RATE Voltage measurement, all ref modes Conversion Time (Note 3) Single-Channel Throughput Power-Up Time ANALOG INPUT (AIN0-AIN7) Input Voltage Range (Note 5) Common-Mode Range Common-Mode Rejection Unipolar, single-ended, or differential inputs Bipolar, differential inputs Differentially configured inputs Differentially configured inputs, VCM = 0 to VDD 0 -VREF / 2 0 -90 +VREF +VREF / 2 VDD V V dB tPU tCONV Temp-sensor ref modes 01, 10 Temp-sensor ref mode 00 Manual trigger, voltage measurement Internal reference (Note 4) 70 40 45 10.6 46 73 11.7 50.7 80 ksps s s SINAD THD SFDR -3dB point S / (N + D) > 68dB Up to the 5th harmonic 70 -76 72 1 100 dB dB dB MHz kHz
2
_______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
ELECTRICAL CHARACTERISTICS (continued)
(VDD = +2.7V to +3.6V (MAX1253), VDD = +4.5V to +5.5V (MAX1254), VREF = +2.5V (MAX1253), VREF = +4.096V (MAX1254), fSCLK = 10MHz (50% duty cycle), TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25C.)
PARAMETER Input Leakage Current Input Capacitance TEMPERATURE MEASUREMENTS Grade A MAX1253 MAX1254 Internal Sensor Measurement Error (Note 7) Grade B MAX1253 Grade B MAX1254 Differential External Sensor Measurement Error (Note 8) Single ended TA = -20C to +85C TA = -40C to +85C TA = +25C TA = -40C to +85C TA = +25C TA = -40C to +85C TA = +25C TA = -40C to +85C TA = +25C TA = -40C to +85C TA = +25C 0.5 0.75 0.3 1.2 0.7 1.2 0.7 2 1 5 2 0.3 0.1 0.125 Low High PSR Differentially configured inputs and internal sensor Single-ended configured, external sensor INTERNAL REFERENCE REF Output Voltage REF Temperature Coefficient REF Output Resistance REF Output Noise REF Power-Supply Rejection Ratio EXTERNAL REFERENCE REF Input Voltage Range REF Input Current VREF IREF VREF = +2.5V; fSAMPLE = 94ksps In power-down 1.0 15 VDD + 0.05 40 1 V A PSRR MAX1253 MAX1254 MAX1253 MAX1254 VREF TCREF MAX1253 MAX1254 Grade A Grade B 2.456 4.024 2.500 4.096 8 30 7 200 160 -70 -70 -50 -50 2.544 4.168 V ppm/C k VRMS dB 4 66 0.3 0.1 C/LSB A C C 3.0 2.5 C 1.0 1.5 SYMBOL (Note 6) CONDITIONS On-/off-leakage, VIN = 0 or VDD 18 MIN TYP MAX 1 UNITS A pF
MAX1253/MAX1254
Temperature Measurement Noise Temperature Resolution External Sensor Bias Current
Differentially configured inputs and internal sensor Single-ended configured, external sensor
Power-Supply Rejection
C/V
_______________________________________________________________________________________
3
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
ELECTRICAL CHARACTERISTICS (continued)
(VDD = +2.7V to +3.6V (MAX1253), VDD = +4.5V to +5.5V (MAX1254), VREF = +2.5V (MAX1253), VREF = +4.096V (MAX1254), fSCLK = 10MHz (50% duty cycle), TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25C.)
PARAMETER DIGITAL INPUTS (SCLK, DIN, CS) Input Voltage Low Input Voltage High Input Hysteresis Input Leakage Current Input Capacitance DIGITAL OUTPUTS (INT, DOUT) Output Voltage Low Output Voltage High Tri-State Leakage Current Tri-State Output Capacitance POWER REQUIREMENTS Positive Supply Voltage VDD MAX1253 MAX1254 MAX1253 internal reference (Note 9) MAX1253 internal reference (Note 10) MAX1253 external reference (Note 10) Supply Current IDD MAX1254 internal reference (Note 9) MAX1254 internal reference (Note 10) MAX1254 external reference (Note 10) Both internal reference, mode 01 (Note 11) Full Power-Down Supply Current Power-Supply Rejection Ratio ISHDN PSRR Full power-down state MAX1253 MAX1254 8 480 860 0.4 1.6 2.7 4.5 3.6 5.5 3.3 2.9 2.2 5.0 4.0 3.0 A nA mV/V mA V VOL VOH IL COUT ISINK = 8mA, DOUT ISINK = 2mA, INT ISOURCE = 8mA, DOUT ISOURCE = 2mA, INT CS = VDD CS = VDD 5 VDD - 0.5 VDD - 0.5 10 0.5 0.5 V V A pF VIL VIH VHYST IIN CIN VIN = 0 or VDD 2 VDD x 0.7 200 10 VDD x 0.3 V V mV A pF SYMBOL CONDITIONS MIN TYP MAX UNITS
Analog inputs at full scale (Note 12)
4
_______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
TIMING CHARACTERISTICS
(VDD = +2.7V to +3.6V (MAX1253), VDD = +4.5V to +5.5V (MAX1254), TA = TMIN to TMAX, unless otherwise noted.) (Figures 1, 2, and 4)
PARAMETER SCLK Clock Period SCLK Pulse Width High Time SCLK Pulse Width Low Time DIN to SCLK Setup Time DIN to SCLK Hold Time CS Fall to SCLK Rise Setup SCLK Rise to CS Rise Hold SCLK Fall to DOUT Valid CS Rise to DOUT Disable CS Fall to DOUT Enable CS Pulse Width High SYMBOL tCP tCH tCL tDS tDH tCSS tCSH tDOV tDOD tDOE tCSW CL = 30pF CL = 30pF CL = 30pF 40 CONDITIONS MIN 100 45 45 25 0 25 50 50 40 40 TYP 0.5 MAX UNITS ns ns ns ns ns ns ns ns ns ns ns
MAX1253/MAX1254
Note 1: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the gain and offset errors have been calibrated. Note 2: Offset nulled. Note 3: In reference mode 00, the reference system powers up for each temperature measurement. In reference mode 01, the reference system powers up once per sequence of channels scanned. If a sample wait <80s is programmed, the reference system is on all the time. In reference mode 10, the reference system is on all the time (see Table 7). Note 4: No external capacitor on REF. Note 5: The operational input voltage range for each individual input of a differentially configured pair (AIN0-AIN7) is from GND to VDD. The operational input voltage difference is from -VREF/2 to +VREF/2. Note 6: See Figure 3 and the Sampling Error vs. Input Source Impedance graph in the Typical Operating Characteristics section. Note 7: Grade A tested at +10C and +55C. -20C to +85C and -40C to +85C specifications guaranteed by design. Grade B tested at +25C. TMIN to TMAX specification guaranteed by design. Note 8: External temperature measurement mode using an MMBT3904 (Diodes Inc.) as a sensor. External temperature sensing from -40C to +85C; MAX1253/MAX1254 held at +25C. Note 9: Performing eight single-ended external channels' temperature measurements, an internal temperature measurement, and an internal VDD measurement with no sample wait results in a conversion rate of 2ksps per channel. Note 10: Performing eight single-ended voltage measurements, an internal temperature measurement, and an internal VDD measurement with no sample wait results in a conversion rate of 7ksps per channel. Note 11: Performing eight single-ended voltage measurements, an internal temperature measurement, and an internal VDD measurement with maximum sample wait results in a conversion rate of 3ksps per channel. Note 12: Defined as the shift in the code boundary as a result of supply voltage change. VDD = min to max; full-scale input, measured using external reference.
_______________________________________________________________________________________
5
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
Typical Operating Characteristics
(VDD = +3V, VREF = 2.5V (MAX1253); VDD = 5V, VREF = 4.096V (MAX1254); fSCLK = 10MHz, CREF = 0.1F, TA = +25C, unless otherwise noted.)
INTEGRAL NONLINEARITY vs. DIGITAL OUTPUT CODE
MAX1253/54 toc01
DIFFERENTIAL NONLINEARITY vs. DIGITAL OUTPUT CODE
MAX1253/54 toc02
INTERNAL REFERENCE VOLTAGE vs. SUPPLY VOLTAGE
2.509 2.508 2.507 2.506 2.505 2.504 2.503 2.502 2.501 2.500 MAX1253
MAX1253/54 toc03
1.0 0.8 0.6 0.4
1.0 0.8 0.6 0.4 DNL (LSB) 0.2 0 -0.2 -0.4 -0.6 -0.8 -1.0
2.510 INTERNAL REFERENCE VOLTAGE (V)
INL (LSB)
0.2 0 -0.2 -0.4 -0.6 -0.8 -1.0 0 1024 2048 OUTPUT CODE 3072 4096
0
1024
2048 OUTPUT CODE
3072
4096
2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 SUPPLY VOLTAGE (V)
INTERNAL REFERENCE VOLTAGE vs. SUPPLY VOLTAGE
MAX1253/54 toc04
REFERENCE VOLTAGE vs. TEMPERATURE
2.508 REFERENCE VOLTAGE (V) 2.506 2.504 2.502 2.500 2.498 2.496 2.494 2.492 GRADE A GRADE B MAX1253
MAX1253/54 toc05
REFERENCE VOLTAGE vs. TEMPERATURE
MAX1254 4.0875 REFERENCE VOLTAGE (V) 4.0850 4.0825 4.0800 4.0775 4.0750 GRADE B 4.0725 4.0700 GRADE A
MAX1253/54 toc05b
4.085 MAX1254 INTERNAL REFERENCE VOLTAGE (V) 4.083
2.510
4.0900
4.081
4.079
4.077
4.075 4.5 4.6 4.7 4.8 4.9 5.0 5.1 5.2 5.3 5.4 5.5 SUPPLY VOLTAGE (V)
2.490 -40 -20 0 20 40 60 80 TEMPERATURE (C)
-40
-20
0
20
40
60
80
TEMPERATURE (C)
SUPPLY CURRENT vs. SAMPLE RATE
MAX1253/54 toc06
SUPPLY CURRENT vs. SAMPLE RATE
MAX1253/54 toc07
SUPPLY CURRENT vs. SUPPLY VOLTAGE
4.2 3.8 SUPPLY CURRENT (mA) 3.4 3.0 2.6 2.2 1.8 9 VOLTAGE CHANNELS AND 1 TEMPERATURE CHANNEL EXTERNAL REFERENCE (MODE 00) 9 TEMPERATURE CHANNELS AND 1 VOLTAGE CHANNEL
MAX1253/54 toc08
10
INTERNAL REFERENCE (MODE 01) MAX1253 9 TEMPERATURE CHANNELS AND 1 VOLTAGE CHANNEL (VDD/2) 9 VOLTAGE CHANNELS AND 1 TEMPERATURE CHANNEL 1 VOLTAGE CHANNEL (VDD/2) 0.01 0.1 1 10
10
INTERNAL REFERENCE (MODE 01) MAX1254 9 TEMPERATURE CHANNELS AND 1 VOLTAGE CHANNEL 9 VOLTAGE CHANNELS AND 1 TEMPERATURE CHANNEL 1 VOLTAGE CHANNEL (VDD/2) 0.01 0.1 1 10
SUPPLY CURRENT (mA)
SUPPLY CURRENT (mA)
1
1
0.1
0.1
0.01
0.01
1.4 1.0 100 2.7 3.1 3.5 3.9
1 VOLTAGE CHANNEL (VDD/2) 4.3 4.7 5.1 5.5
0.001 0.001
100
0.001 0.001
SAMPLE RATE (kHz)
SAMPLE RATE (kHz)
SUPPLY VOLTAGE (V)
6
_______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Typical Operating Characteristics (continued)
(VDD = +3V, VREF = 2.5V (MAX1253); VDD = 5V, VREF = 4.096V (MAX1254); fSCLK = 10MHz, CREF = 0.1F, TA = +25C, unless otherwise noted.)
SUPPLY CURRENT vs. SUPPLY VOLTAGE
MAX1253/54 toc09
MAX1253/MAX1254
SUPPLY CURRENT vs. TEMPERATURE
MAX1253/54 toc10
SUPPLY CURRENT vs. TEMPERATURE
INTERNAL REFERENCE (MODE 01) MAX1254 4.5 SUPPLY CURRENT (mA) 4.0 3.5 3.0 1 VOLTAGE CHANNEL (VDD/2) 2.5 2.0 9 TEMPERATURE CHANNELS AND 1 VOLTAGE CHANNEL (VDD/2) 9 VOLTAGE CHANNELS AND 1 TEMPERATURE CHANNEL
MAX1253/54 toc11
4.3 3.9 SUPPLY CURRENT (mA) 3.5 3.1 2.7 2.3 1.9 1.5
INTERNAL REFERENCE (MODE 01) 9 TEMPERATURE CHANNELS AND VOLTAGE CHANNEL (VDD/2) 9 VOLTAGE CHANNELS AND 1 TEMPERATURE CHANNEL
2.6 2.5 2.4 SUPPLY CURRENT (mA) 2.3 2.2 2.1 2.0 1.9 1.8 1.7 1.6 INTERNAL REFERENCE (MODE 01) MAX1253 -40 -25 -10 5 20 35 50 65 80 1 VOLTAGE CHANNEL (VDD/2) 9 VOLTAGE CHANNELS AND 1 TEMPERATURE CHANNEL 9 TEMPERATURE CHANNELS AND 1 VOLTAGE CHANNEL (VDD/2)
5.0
1 VOLTAGE CHANNEL (VDD/2) 2.7 3.1 3.5 3.9 4.3 4.7 5.1 5.5
-40 -25 -10
5
20
35
50
65
80
SUPPLY VOLTAGE (V)
TEMPERATURE (C)
TEMPERATURE (C)
SHUTDOWN SUPPLY CURRENT vs. SUPPLY VOLTAGE
MAX1253/54 toc12
SHUTDOWN SUPPLY CURRENT vs. TEMPERATURE
MAX1253/54 toc13
GAIN AND OFFSET ERROR vs. SUPPLY VOLTAGE
0.80 GAIN AND OFFSET ERROR (LSB) 0.60 0.40 0.20 0 -0.20 -0.40 -0.60 -0.80 -1.00 MAX1254 GAIN ERROR MAX1253 SINGLE ENDED OFFSET ERROR
MAX1253/54 toc14
1.00
700 SHUTDOWN SUPPLY CURRENT (nA) 600 MAX1254 500 400 300 200 100 2.7 3.1 3.5 3.9 4.3 4.7 5.1
700 SHUTDOWN SUPPLY CURRENT (nA) 600 500 400 300 200 100 0 MAX1253 VDD = 3V -40 -25 -10 5 20 35 50 65 80 MAX1254 VDD = 5V
MAX1253
5.5
2.7
3.1
3.5
3.9
4.3
4.7
5.1
5.5
SUPPLY VOLTAGE (V)
TEMPERATURE (C)
SUPPLY VOLTAGE (V)
GAIN ERROR vs. TEMPERATURE
MAX1253/54 toc15
OFFSET ERROR vs. TEMPERATURE
MAX1253/54 toc16
INTERNAL TEMPERATURE SENSOR TEMPERATURE ERROR
MAX1253/MAX1254 0.80 0.60 0.40 GRADE A INTERNAL SENSOR ERROR (C)
MAX1253/54 toc17
1.00 0.90 0.80 GAIN ERROR (LSB) 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0 -0.10
OFFSET ERROR (LSB)
UNIPOLAR DIFFERENTIAL CONFIGURATION EXTERNAL REFERENCE MODE
BIPOLAR DIFFERENTIAL CONFIGURATION EXTERNAL REFERENCE MODE
0.40 0.20 0 -0.20 -0.40 -0.60 -0.80 -1.00 UNIPOLAR DIFFERENTIAL CONFIGURATION EXTERNAL REFERENCE MODE
UNIPOLAR SINGLE-ENDED CONFIGURATION EXTERNAL REFERENCE MODE
1.00
BIPOLAR DIFFERENTIAL CONFIGURATION EXTERNAL REFERENCE MODE
0.20 0 -0.20 -0.40 -0.60 -0.80 -1.00 GRADE B INTERNAL SENSOR
UNIPOLAR SINGLE-ENDED CONFIGURATION EXTERNAL REFERENCE MODE -40 -25 -10 5 20 35 50 65 80
-40 -25 -10
5
20
35
50
65
80
-40
-20
0
20
40
60
80
TEMPERATURE (C)
TEMPERATURE (C)
TEMPERATURE (C)
_______________________________________________________________________________________
7
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
Typical Operating Characteristics (continued)
(VDD = +3V, VREF = 2.5V (MAX1253); VDD = 5V, VREF = 4.096V (MAX1254); fSCLK = 10MHz, CREF = 0.1F, TA = +25C, unless otherwise noted.)
EXTERNAL TEMPERATURE SENSOR TEMPERATURE ERROR
MAX1253/54 toc18
TEMPERATURE ERROR vs. INTERCONNECT CAPACITANCE (EXTERNAL SENSOR)
MAX1253/54 toc19
2.0 1.6 1.2 0.8 ERROR (C) 0.4 0 -0.4 -0.8 -1.2 -1.6 -2.0 -40 -20 0 20 40 60 80 TEMPERATURE (C) EXTERNAL SENSOR, SINGLE-ENDED INPUT MAX1253/MAX1254 EXTERNAL SENSOR, DIFFERENTIAL INPUT
1 0 TEMPERATURE (C) -1 -2 -3 -4 -5 -6 1 10 100 EXTERNAL DIODE DIFFERENTIAL TEMPERATURE MEASUREMENT MODE
1000
INTERCONNECT CAPACITANCE (pF)
SAMPLING ERROR vs. INPUT SOURCE IMPEDANCE
MAX1253/54 toc20
IN A TSSOP SOCKET 0.500 TEMPERATURE SHIFT (C) 0.375 0.250 0.125 0 -0.125 EXTERNAL BJT 0 5 10 15 TIME (s) 20 25 SOLDER ON A 2in 2in PWB
0 SAMPLING ERROR (LSB) -1 -2 -3 -4 -5 10 100 1000
IN AN OIL BATH
10,000
30
SOURCE IMPEDANCE ()
8
_______________________________________________________________________________________
MAX1253/54 toc21
1
0.625
TURN ON THERMAL TRANSIENT, CONTINUOUS CONVERSION VDD = 3.0V
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Block Diagram
VDD
MAX1253/MAX1254
REFERENCE INPUT CHANNEL REGISTER INPUT CONFIGURATION REGISTER STEP-UP REGISTER ALARM REGISTER AIN1 AIN2 AIN3 AIN4 AIN5 AIN6 AIN7 SCAN AND CONVERSION CONTROL POR INTERNAL TEMP VDD/2 AIN0 POWERGOOD AIN1 AIN2 AIN3 AIN4 AIN5 AIN6 AVERAGING DIGITAL COMPARATOR AIN7 MUX SERIAL INTERFACE 12-BIT ADC WITH T/H
REF
TEMP SENSOR
MAX1253 MAX1254
DOUT DIN SCLK CS
INT
ACCUMULATOR ACCUMULATOR ACCUMULATOR ACCUMULATOR ACCUMULATOR ACCUMULATOR ACCUMULATOR ACCUMULATOR ACCUMULATOR ACCUMULATOR UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD UPPER THRESHOLD LOWER THRESHOLD
CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION
Pin Description
PIN NAME 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 AIN0 AIN1 AIN2 AIN3 AIN4 AIN5 AIN6 AIN7 REF INT GND VDD DIN SCLK CS FUNCTION Analog Voltage Input/Temperature Input Channel 0 or Positive Differential Input Relative to AIN1 Analog Voltage Input/Temperature Input Channel 1 or Negative Differential Input Relative to AIN0 Analog Voltage Input/Temperature Input Channel 2 or Positive Differential Input Relative to AIN3 Analog Voltage Input/Temperature Input Channel 3 or Negative Differential Input Relative to AIN2 Analog Voltage Input/Temperature Input Channel 4 or Positive Differential Input Relative to AIN5 Analog Voltage Input/Temperature Input Channel 5 or Negative Differential Input Relative to AIN4 Analog Voltage Input/Temperature Input Channel 6 or Positive Differential Input Relative to AIN7 Analog Voltage Input/Temperature Input Channel 7 or Negative Differential Input Relative to AIN6 Positive Reference Input in External Mode. Bypass REF with a 0.1F capacitor to GND when in external mode. When using the internal reference, REF must be left open. Interrupt Output. Push-pull or open drain with selectable polarity. See Table 9 and the INT Interrupt Output section. Ground Positive Power Supply. Bypass with a 0.1F capacitor to GND. Serial Data Input. DIN data is latched into the serial interface on the rising edge of the SCLK. Serial Clock Input. Clocks data in and out of the serial interface (duty cycle must be 40% to 60%). Active-Low Chip-Select Input. When CS is low, the serial interface is enabled. When CS is high, DOUT is high impedance, and the serial interface resets.
DOUT Serial Data Output. DOUT transitions on the falling edge of SCLK. High impedance when CS is at logic high.
_______________________________________________________________________________________
9
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
VDD VDD
100nA
100nA
DOUT
DOUT
DOUT
DOUT
100nA
CLOAD = 100pF
CLOAD = 100pF
100nA
CLOAD = 100pF
CLOAD = 100pF
GND a) VOL TO VOH
GND b) HIGH-Z TO VOL AND VOH TO VOL
GND a) VOH TO HIGH-Z
GND b) VOL TO HIGH-Z
Figure 1. Load Circuits for DOUT Enable Time and SCLK to DOUT Delay Time
Figure 2. Load Circuit for DOUT Disable Time
Detailed Description
The MAX1253/MAX1254 are precision-monitoring integrated circuit systems specifically intended for standalone operation. They can monitor diverse types of inputs, such as those from temperature sensors and voltage signals from pressure, vibration, and acceleration sensors, and digitize these input signals. The digital values are then compared to preprogrammed thresholds and, if the thresholds are exceeded, the processor is alerted by an interrupt signal. No interaction by the CPU or microcontroller (C) is required until one of the programmed limits is exceeded (Figures 3 and 4). Voltages on all the inputs are converted to 12-bit values sequentially and stored in the current data registers. Note that eight of these inputs are external and two are internal. One of the internal inputs monitors the VDD voltage supply, while the other monitors the internal IC temperature. AIN0 to AIN7 can be configured as either single ended (default) or differential. In addition, these inputs can be configured for single-ended or differential temperature measurements. In the temperature configuration, the device provides the proper bias necessary to measure temperature with a diode-connected transistor sensor. The user enables which inputs are measured (both external and internal) and sets the delay between each sequence of measurements during the initial setup of the device. The values stored in the current data registers are compared to the user-preprogrammed values in the threshold registers (upper and lower thresholds) and, if exceeded, activate the interrupt output and generate an
10
alarm condition. If desired, the device can be programmed to average the results of many measurements before comparing to the threshold value. This reduces the sensitivity to external noise in the measured signal. In addition, the user can set the number of times the threshold is exceeded (fault cycles) before generating an interrupt. This feature reduces falsely triggered alarms caused by undesired, random spurious impulses. When the fault cycle criterion is exceeded, an alarm condition is created. The device writes the fault condition into the alarm register to indicate the alarmed input channel.
Converter Operation
The MAX1253/MAX1254 ADCs use a fully differential successive-approximation register (SAR) conversion technique and an on-chip track-and-hold (T/H) block to convert temperature and voltage signals into a 12-bit digital result. Both single-ended and differential configurations are supported with a unipolar signal range for single-ended mode and bipolar or unipolar ranges for differential mode. Figure 5 shows the equivalent input circuit for the MAX1253/MAX1254. Configure the input channels according to Tables 5 and 6 (see the Input Configuration Register section). In single-ended mode, the positive input (IN+) is connected to the selected input channel and the negative input (IN-) is connected to GND. In differential mode, IN+ and IN- are selected from the following pairs: AIN0/AIN1, AIN2/AIN3, AIN4/AIN5, and AIN6/AIN7. Once initiated, voltage conversions require 10.6s (typ) to complete.
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
VDD
AIN0 AIN1 AIN2 AIN3 AIN4 AIN5 AIN6 AIN7 MUX 12-BIT ADC WITH T/H
INPUT REGISTERS CURRENT DATA UPPER THRESHOLD LOWER THRESHOLD # FAULT CYCLES AVERAGE CONFIGURATION/ STATUS REGISTERS DIGITAL COMPARATOR INT
SCAN AND CONVERSION CONTROL
SERIAL INTERFACE TEMP SENSE
DIN DOUT SCLK CS
Figure 3. Simplified Alarm Block Diagram of the MAX1253/MAX1254
During the acquisition interval, IN+ and IN- charge both a positive (CHOLDP) and a negative (CHOLDN) sampling capacitor. After completing the acquisition interval, the T/H switches open, storing an accurate sample of the differential voltage between IN+ and IN-. This charge is then transferred to the ADC and converted. Finally, the conversion result is transferred to the current data register. Temperature conversions require 46s (typ) and measure the difference between two sequential voltage measurements (see the Temperature Measurement section for a detailed description).
Input Bandwidth
The ADC's input tracking circuitry has a 1MHz smallsignal bandwidth. To avoid high-frequency signals aliasing into the frequency band of interest, anti-alias prefiltering of the input signals is recommended.
Analog Input Protection
Internal protection diodes, which clamp the analog inputs to VDD and GND, allow the channel input pins to swing from (GND - 0.3V) to (VDD + 0.3V) without damage. However, for accurate conversions near full scale, the inputs must not exceed VDD by more than 50mV or be lower than GND by 50mV. If the analog input range must exceed 50mV beyond the supplies, limit the input current. Single Ended/Differential The MAX1253/MAX1254 use a fully differential ADC for all conversions. Through the input configuration register, the analog inputs can be configured for either differential or single-ended conversions. When sampling signal sources close to the MAX1253/MAX1254, singleended conversion is generally sufficient. Single-ended conversions use only one analog input per signal source, internally referenced to GND.
11
Fully Differential Track/Hold (T/H)
The T/H acquisition interval begins with the rising edge of CS (for manually triggered conversions) and is internally timed to 1.5s (typ). The accuracy of the input signal sample is a function of the input signal's source impedance and the T/H's capacitance. In order to achieve adequate settling of the T/H, limit the signal source impedance to a maximum of 1k.
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
INCREMENT CHANNEL COUNTER
IS CHANNEL ENABLED?
NO
YES
SAMPLE CHANNEL
CONVERT CHANNEL
AVERAGE CONVERTED CHANNEL DATA
INCREMENT FAULT COUNTER
YES
SAME FAULT AS PREVIOUS?
YES
IS AVG DATA > UPPER?
NO
YES
NO
RESET FAULT COUNTER
IS AVG DATA < LOWER?
NO
IS FAULT CNT > FAULT REG?
NO
YES
SET ALARM REGISTER
Figure 4. Alarm Flowchart 12 ______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
VDD VDD
T CHOLDP 8-TO-1 DIFFERENTIAL MUX H CHOLDN T T H TEMP VAZ DIFFERENTIAL INPUT EQUIVALENT INPUT CIRCUIT T H TEMP ADC 8-TO-1 DIFFERENTIAL MUX H
T CHOLD ADC
T
H
VAZ SINGLE-ENDED INPUT EQUIVALENT INPUT CIRCUIT
Figure 5. Single-Ended/Differential Input Equivalent Input Circuit
In differential mode, the T/H samples the difference between two analog inputs, eliminating common-mode DC offsets and noise. See the Input Configuration Register section and Tables 5 and 6 for more details on configuring the analog inputs. Unipolar/Bipolar When performing differential conversions, the input configuration register (Tables 5 and 6) also selects between unipolar and bipolar operation. Unipolar mode sets the differential input range from 0 to VREF. A negative differential analog input in unipolar mode causes the digital output code to be zero. Selecting bipolar mode sets the differential input range to VREF/2. The digital output code is straight binary in unipolar mode and two's complement in bipolar mode (see the Transfer Function section). In single-ended mode, the MAX1253/MAX1254 always operate in unipolar mode. The analog inputs are internally referenced to GND with a full-scale input range from 0 to VREF.
Digital Interface
The MAX1253/MAX1254 digital interface consists of five signals: CS, SCLK, DIN, DOUT, and INT. CS, SCLK, DIN, and DOUT comprise an SPITM-compatible serial interface (see the Serial Digital Interface section). INT is an independent output that provides an indication that an alarm has occurred in the system (see the INT Interrupt Output section).
Serial Digital Interface
The MAX1253/MAX1254 feature a serial interface compatible with SPI, QSPITM, and MICROWIRETM devices. For SPI/QSPI, ensure that the CPU serial interface runs in master mode so it generates the serial clock signal. Select a serial clock frequency of 10MHz or less, and set clock polarity (CPOL) and phase (CPHA) in the P control registers to the same value, one or zero. The MAX1253/MAX1254 support operation with SCLK idling high or low, and thus operate with CPOL = CPHA = 0 or CPOL = CPHA = 1.
SPI and QSPI are trademarks of Motorola, Inc. MICROWIRE is a trademark of National Semiconductor Corp. ______________________________________________________________________________________ 13
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
CS tCSW tCSS tCH tCSH
tCL
tCP
SCLK tDS tDH DIN tDOV HIGH-Z DOUT tDOE tDOD HIGH-Z
Figure 6. Detailed Serial Interface Timing Diagram
Clock pulses on SCLK shift data into DIN on the rising edge of the SCLK and out of DOUT on the falling edge of SCLK. Data transfers require a logic low on CS. A high-to-low transition of CS marks the beginning of a data transfer. A logic high on CS at any time resets the serial interface. See Figure 6 and the Timing Characteristics table for detailed serial-interface timing information.
Output Data Format
Output data from the MAX1253/MAX1254 is clocked onto DOUT on the falling edge of SCLK. Single-ended and unipolar differential measurements are output in straight binary MSB first, with two 8-bytes-per-conversion result, and the last 4 bits padded with zeros. For temperature and bipolar differential voltage measurements, the output is two's complement binary in the same 2-byte format. The MSB of the output data from a read command transitions at DOUT after the falling edge of the 8th SCLK clock pulse following the CS high-to-low transition. Table 2 shows the number of bytes to be read from DOUT for a given read command.
Input Data Format
Serial communications always begin with an 8-bit command word, serially loaded from DIN. A high-to-low transition on CS initiates the data input operation. The command word and the subsequent data bytes (for write operations) are clocked from DIN into the MAX1253/MAX1254 on the rising edges of SCLK. The first rising edge on SCLK, after CS goes low, clocks in the MSB of the command word (see the Command Word section). The next seven rising edges on SCLK complete the loading of the command word into the internal command register. After the 8-bit command word is entered, transfer 0 to 20 bytes of data, depending on the command. Table 2 shows the number of data bytes for each command.
Command Word
The command word (Table 1) controls all serial communications and configuration of the MAX1253/ MAX1254, providing access to the 44 on-chip registers. The first 4 MSBs of the command word specify the command (Table 2), while the last 4 bits provide address information. The first rising edge on SCLK, after CS goes low, transfers the command word MSB into DIN. The next seven rising edges on SCLK shift the remaining 7 bits into the internal command register (see the Serial Digital Interface section).
Table 1. Command Word
B7 (MSB) Command B3 B6 Command B2 B5 Command B1 B4 Command B0 B3 Address B3 B2 Address B2 B1 Address B1 B0 (LSB) Address B0
14
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Table 2. Command Description
COMMAND WORD 0000#### 0001xxxx 0010#### 0011#### 0100#### 0101xxxx 0110xxxx 0111xxxx 1000#### 1001xxxx 1010#### 1011xxxx 1100#### 1101xxxx 1110xxxx 1111xxxx DATA BYTES AFTER COMMAND WORD COMMAND DESCRIPTION BYTES TO DIN 0 0 0 0 0 0 N/A 0 0 0 2 20 5 5 N/A N/A BYTES FROM DOUT 0 3 2 20 5 5 N/A 0 0 0 0 0 0 0 N/A N/A Manually Trigged Conversion Read Alarm Register Read Current Data Register for Selected Channel Read Current Data Register for All Channels Read Configuration Register for Selected Channel Read Global Configuration Registers Reserved Reset Clear Alarm/Fault for Selected Channels Clear Alarm/Fault for All Channels Write Current Data Register for Selected Channel Write Current Data Registers for All Channels Write Configuration Registers for Selected Channel Write Global Configuration Registers Reserved Reserved
MAX1253/MAX1254
#### = Channel address code, see Table 3. xxxx = These bits are ignored for this command.
Table 3. Channel Address
ADDRESS IN COMMAND 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 INPUT Internal temperature VDD AIN0 AIN1 AIN2 AIN3 AIN4 AIN5 AIN6 AIN7 Reserved Reserved Reserved Reserved Reserved Reserved
Manually Triggered Conversion (Command Code = 0000)
Before beginning a manual conversion, ensure the scan mode bit in the setup register is zero, because a logic 1 disables manual conversions. The address bits in a Manually Triggered Conversion command select the input channel for conversion (see Table 3). When performing a differential conversion, use the even channel address (AIN0, AIN2, AIN4, AIN6); the command is ignored if odd channel addresses (AIN1, AIN3, AIN5, AIN7) are used for a differential conversion. After issuing a Manually Triggered Conversion command, bring CS high to begin the conversion. To obtain a correct conversion result, CS must remain high for a period longer than the reference power-up time (if in power-down mode) plus the conversion time for the selected channel configured conversion type (voltage or temperature). The conversion's result can then be read at DOUT by issuing a Read Current Data Register for Selected Channel command, addressing the converted channel. See Table 3 for channel addresses.
______________________________________________________________________________________
15
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
Read Alarm Register (Command Code 0001)
The Read Alarm Register command, 0001, outputs the current status of the alarm register (see Table 11). The address bits in this command are ignored. The alarm register is 24 bits long and outputs in 3 bytes. Table 12 illustrates the encoding of the alarm register. After receiving an interrupt, read the alarm register to determine the source of the interrupt (see the Alarm Register section).
Read Current Data Register for All Channels (Command Code 0011)
The Read Current Data Registers for All Channels command, 0011, outputs the data in the current data registers of all 10 channels starting with the internal temperature sensor, then the VDD monitor, followed by AIN0 to AIN7. The address bits following this command are ignored. It takes 20 bytes to read all of the 10 channels' current data registers.
Read Current Data Register for Selected Channel (Command Code 0010)
The Read Current Data Register for Selected Channel command, 0010, outputs the data in the current data register of the selected channel. The address bits following this command select the input channel to be read (see Table 3). The current data register is a 12-bit register. It takes 2 bytes to read its value. See the Output Data Format and Current Data Registers sections for more details. See Table 3 for channel addresses. Also, see Figure 7.
Read Configuration Register for Selected Channel (Command Code 0100)
The Read Configuration Register for Selected Channel command, 0100, outputs the configuration data of the channel selected by the address bits (see Table 3). The first register that shifts out is the upper threshold register (2 bytes), followed by the lower threshold register (2 bytes), ending with the channel configuration register (1 byte), all MSB first. It takes 5 bytes to read all three registers. See the Channel Registers section for more details.
CS
SCLK
DIN
C3
C2 C1 C0
A3
A2
A1 A0
DOUT
D11
D10
D9
D8 D7
D6
D5
D4
D3
D2
D1
D0
Figure 7. Serial Register Read Timing
16
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Read Global Configuration Register (Command Code 0101)
The Read Global Configuration Register command, 0101, outputs the global configuration registers. The address bits following this command are ignored. When the MAX1253/MAX1254 receive a read global configuration register command, they output 5 bytes of data: 2 bytes from the channel enable register, 2 bytes from the input configuration register, and 1 byte from the setup register, all MSB first. See the Global Configuration Registers section for more details.
Clear Alarm Register for All Channels (Command Code 1001)
The Clear Alarm Register for All Channels command, 1001, clears the entire alarm register and resets the fault counters for the internal TEMP sensor, the VDD monitor, and the AIN0-AIN7 channels. The address bits in the command are ignored. See the Alarm Register section for more details.
MAX1253/MAX1254
Write Current Data Register for Selected Channel (Command Code 1010)
The Write Current Data Register for Selected Channel command, 1010, writes to the addressed channel's current data register. This command sets an initial condition when using the averaging filter option (see the Averaging section). This command can also be used for testing the thresholds, fault counters, and alarm functions (Figure 8). See Table 3 for channel addresses.
RESET (Command Code 0111)
The RESET command, 0111, resets the device. This command returns the MAX1253/MAX1254 to their power-on reset state, placing the device into shutdown mode. The address bits in the command are ignored. See the Power-Up/Reset Defaults Summary section for more details.
Clear Channel Alarm for Selected Channel (Command Code 1000)
The Clear Channel Alarm command, 1000, clears the alarm bits in the alarm register and resets the fault counter for the addressed channel. See the Alarm Register section for more details. See Table 3 for channel addresses.
Write Current Data Register for All Channels (Command Code 1011)
The Write Current Data Register for All Channels command, 1011, writes to the current data registers of all channels sequentially, starting with the internal temperature sensor, then the VDD monitor, followed by channels AIN0 to AIN7. The address bits are ignored. Use this command for testing and setting initial conditions when using the averaging filter option (see the Averaging section).
CS
SCLK
DIN
C3 C2 C1 C0
A3
A2
A1
A0
D11 D10 D9
D8
D7
D6
D5
D4
D3 D2 D1
D0
HIGH-Z DOUT
HIGH-Z
Figure 8. Serial Register Write Timing ______________________________________________________________________________________ 17
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
Write-Selected Channel Configuration Registers (Command Code 1100)
The Write-Selected Channel Configuration Register command, 1100, writes to the three channel configuration registers for the addressed channel (see Table 3). The first register to be written is the upper threshold (2 bytes), followed by the lower threshold (2 bytes), ending with the channel configuration register (1 byte), all MSB first. Writing to the configuration registers resets the alarm register bits and the fault counters for the addressed channel. See the Channel Registers section for more details.
Channel-Enable Register
The channel-enable register (Table 4) controls which channels are converted while in automatic scan mode. The register contents are ignored for manual conversion commands. Each input channel has a corresponding bit in the channel-enable register. A logic high enables the corresponding analog input channel for conversion, while a logic low disables it. In differential configuration, the bits for odd channels are ignored. At power-up and after a RESET command, the register contents default to 111111111111b (all channels enabled).
Write Global Configuration Registers (Command Code 1101)
The Write Global Configuration Registers command, 1101, writes to three registers: the channel-enable register (2 bytes), the input configuration register (2 bytes), and the setup register (1 byte). The command address bits are ignored. See the Global Configuration Registers section for more details.
Input Configuration Register
The input configuration register (Table 5) stores the configuration code for each channel as a 3-bit per channel-pair code (see Table 6), selecting from five input signal configurations: single-ended unipolar voltage, single-ended temperature, differential unipolar voltage, differential bipolar voltage, and differential temperature. Table 5 shows the input configuration register format, and Table 6 shows the 3-bit encoding for channel configuration. At power-up and after a RESET command, the register contents defaults to 000000000000b (all inputs single ended).
Global Configuration Registers
The global configuration registers consist of the channel-enable register, the input configuration register, and the setup register. These registers hold configuration data common to all channels.
Table 4. Channel-Enable Register Format
B11 (MSB) TEMP B10 VDD B9 AIN0 B8 AIN1 B7 AIN2 B6 AIN3 B5 AIN4 B4 AIN5 B3 AIN6 B2 AIN7 B1 Res B0 (LSB) Res
Table 5. Input Configuration Register Format
B11 (MSB) B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 (LSB)
AIN0 and AIN1 configuration
AIN2 and AIN3 configuration
AIN4 and AIN5 configuration
AIN6 and AIN7 configuration
Table 6. Channel Configuration Coding (3 Bits/Channel Pair)
CODE 000 001 010 011 100 101 110 111 AIN0, AIN2, AIN4, AIN6 CONFIGURATION Single-ended input (power-up state) Single-ended input Single-ended, external temperature sensor input Single-ended, external temperature sensor input Differential unipolar encoded, positive input Differential bipolar encoded, positive input Differential external temperature sensor, positive input Reserved AIN1, AIN3, AIN5, AIN7 CONFIGURATION Single-ended input (power-up state) Single-ended, external temperature sensor input Single-ended input Single-ended, external temperature sensor input Differential unipolar encoded, negative input Differential bipolar encoded, negative input Differential external temperature sensor, negative input Reserved
18
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Setup Register
The 8-bit setup register (Table 7) holds configuration data common to all input channels. At power-up and after a RESET command, this register defaults to 00000000b. Setup Register: Sample Wait Bits (B7, B6, B5) These 3 bits in the setup register (Table 8) set the wait time between conversion scans. The following are examples of how the MAX1253/MAX1254 begin a sample sequence (see the Setup Register: Reference Selection Bits (B1, B0) section). Operating in reference mode 00 (external reference for voltage conversions, internal reference for temperature conversions): 1) Convert the first-enabled channel. If this channel is a temperature measurement, power up the internal reference (this takes 20s for each enabled temperature measurement in reference mode 00). 2) Sequence to the next-enabled channel until all channels have been converted. 3) Wait the sample wait period. 4) Repeat the procedure. Operating in reference mode 01 (internal reference for all conversions, can be powered down between scans): 1) Power up the internal reference, if powered down (this takes 40s). 2) Convert the first-enabled channel, starting with the internal temperature sensor, if enabled. 3) Sequence to the next-enabled channel until all enabled channels have been converted. 4) Wait the sample wait time, and enter internal reference power-down mode if this period is greater than 80s. 5) Repeat the above steps. Operating in reference mode 10 (internal reference for all conversions, continuously powered up): 1) Convert the first-enabled channel. 2) Sequence to the next-enabled channel until all enabled channels have been converted. 3) Wait the sample wait time. 4) Repeat the procedure. Use the sample wait feature to reduce supply current when measuring slow-changing analog signals. This power savings occurs when reference mode 00 or 01 is used in combination with wait times longer than 80s. With reference mode 10 or wait times of less than 80s, the internal reference system remains powered up, minimizing any power savings. See the Computing Data Throughput section. Table 8 shows the B7, B6, B5 wait time encoding. Setup Register: Interrupt Control (B4, B3) Bits B3 and B4 in the setup register configure INT and how it responds to an alarm event (see the Alarm Register section). Table 9 shows the available INT options.
MAX1253/MAX1254
Table 7. Setup Register Format
B7 (MSB) B6 Sample wait bits B5 B4 Interrupt active B3 Interrupt polarity B2 Scan mode B1 Reference source B1 B0 (LSB) Reference source B2
Table 8. Wait Time Encoding
B7, B6, B5 000 001 010 011 100 101 110 111 WAIT TIME (ms) 0 0.080 0.395 1.310 4.970 19.600 78.200 312.000
Table 9. Interrupt Control
BIT FUNCTION BIT STATE 1 B4 Output driver type Output polarity 0 1 0 INT OPERATION Driven high or low at all times High-Z when inactive, driven (high or low) when active Active = high, inactive = low or high-Z Active = low, inactive = high or high-Z
B3
______________________________________________________________________________________
19
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
Setup Register: Scan Mode Bit (B2) The scan mode bit selects between automatic scanning and manual conversion mode. When set (B2 = 1), the MAX1253/MAX1254 enter automatic scanning mode and convert every enabled channel starting with the internal temperature sensor, followed by the VDD monitor, then sequencing through AIN0 to AIN7. After converting all the enabled channels, the MAX1253/MAX1254 enter a wait state set by the sample wait bits in the setup register. After completing the sample wait time, the scan cycle repeats. When B2 = 0, the MAX1253/MAX1254 are in manual mode and convert only the selected channel after receiving a Manually Triggered Conversion command (see the Manually Triggered Conversion (Command Code 0000) section). Whether in automatic scanning mode or manual mode, a Read Current Data Register for Selected Channel command outputs the last-completed conversion result for the addressed channel at DOUT. Setup Register: Reference Selection Bits (B1, B0) The MAX1253/MAX1254 can be used with an internal or external reference. Select between internal and external reference modes through bits B1 and B0 of the setup register (see Table 10).
Alarm Register
The alarm register (Table 11) holds the current alarm status for all of the monitored signals. This 24-bit register can only be read and cleared. The alarm register has 2 bits for each external input channel, 2 for the onboard temperature sensor, and 2 for the VDD monitor (see Table 12). At power-up, these bits are logic low, indicating no alarms at any input. When any bit in the alarm register is set, INT becomes active and remains active until all alarm bits are cleared. After a fault counter exceeds the set threshold, the alarm register bits for that particular channel are updated to indicate an alarm. To clear the interrupt, reset the active alarm bit with the Clear Alarm Register command, Clear Channel Alarm command, a RESET command, or by writing a new configuration to the faulting channel. The alarm register defaults to 000000 hex. Table 11 illustrates how the alarm register stores the information on which channel a fault has occurred. The alarm code for each bit pair is shown in Table 12.
Table 10. Reference Selection
B1 B0 REFERENCE MODE Voltage measurements use external reference, while temperature measurements use the internal reference. A 20s reference startup delay is added prior to each temperature measurement in this mode. This is the default mode after power-up and after a software RESET. All measurements use the internal reference. A 40s reference startup delay is added prior to starting the scanning of enabled channels, allowing the internal reference to stabilize. Note: For sample wait times less than 80s, the reference is continuously powered when in automatic scan mode. All measurements use the internal reference. By selecting this mode, the reference is powered up immediately when CS goes high after writing this configuration. Once the reference system is powered up, no further delay is added. Reserved.
Channel Registers
Each channel (internal temperature sensor, VDD monitor, and AIN0 to AIN7) has registers to hold the conversion result (current data register) and channel-specific configuration data. The channel-specific configuration registers include: the upper threshold register, the lower threshold register, and the channel configuration register. In differential mode, only the registers for the even channel of the differential input pair are used. The channel-specific configuration registers for the odd channel of a differential channel pair are ignored.
0
0
0
1
Table 12. Alarm Register Coding (2 Bits/Channel)
CODE 00 01 10 00 DESCRIPTION No alarm (power-up state) Input is below lower threshold Input is above upper threshold Reserved
1
0
1
1
Table 11. Alarm Register Format
B23/B22 TEMP B21/B20 VDD B19/B18 AIN0 B17/B16 AIN1 B15/B14 AIN2 B13/B12 AIN3 B11/B10 AIN4 B9/B8 AIN5 B7/B6 AIN6 B5/B4 AIN7 B3/B2 Res B1/B0 Res
20
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Table 13. Channel Configuration Register Format
B7 (MSB) Fault B3 B6 Fault B2 B5 Fault B1 B4 Fault B0 B3 Ave B3 B2 Ave B2 B1 Ave B1 B0 (LSB) Ave B0
MAX1253/MAX1254
Table 14. Conversion Average Encoding
CODE 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 N 1, no averaging 2 4 8 16 32 64 128 256 512 1024 2048 Reserved Reserved Reserved Reserved
fault occurs and the next scan finds the input within the normal range defined by the thresholds, the fault counter resets. If the next counter finds the input signal outside the opposite threshold, rather than the previous one, the fault counter also resets. The fault counter increments only when counting consecutive faults exceeding the same threshold (Figure 4).
Averaging
The averaging calculated by the data-acquisition algorithm of the MAX1253/MAX1254 improves the input signal-to-noise ratio (SNR) by reducing the signal bandwidth digitally. The formula below describes the filter implemented in the MAX1253/MAX1254: current value = [(N - 1) / N] x past value + [(present value) / N] where N = number of samples indicated in Table 14. The averaging bits (B3-B0) in the channel configuration register can set the N factor to any value in Table 14. The output of the filter-running algorithm is continuously available in the current data register. The starting value used by the algorithm is the initial state of the current data register. The current data register is reset to midscale (800 hex) at power-up or after a RESET command, but it can be loaded with a more appropriate initial value to improve the filter settling time. At power-up or after a RESET command, the B3-B0 bits of the channel configuration register are set to 0 hex, corresponding to a number of averaged N = 1, no averaging. See Table 13 and the Write-Selected Channel Configuration Registers section for programming details. See Table 14 for N encoding. As in all digital filters, truncation can be a cause of significant errors. In the MAX1253/MAX1254, 24 bits of precision are maintained in the digital averaging function, maintaining a worst-case truncation error of well below an LSB. The worst-case truncation error in the MAX1253/MAX1254 is given by the following: worst - case truncation error = N -1 LSBs 4096
Channel Configuration Register
Each channel has a channel configuration register (Table 13) defining the number of consecutive faults to be detected before setting the alarm bits and generating an interrupt, as well as controlling the digital averaging. At power-up and after a RESET command, the register defaults to 00 hex (no averaging, alarm on first fault).
Fault Bits
The value stored in the fault bits (B7-B4) in the channel configuration register sets the number of faults that must occur for that channel before generating an interrupt. Encoding of the fault bits is straight binary with valves 0 to 15. A fault occurs in a channel when the value in its current data register is outside the range defined by the channel's upper and lower threshold registers. For example, if the number of faults set by the fault bits is N, an interrupt is generated when the number of consecutive faults (see note below) reach (N + 1). The fault bits default to 0 hex at power-up. Note: Consecutive faults are those happening in consecutive conversion scans for the same channel. If a
where N = number of conversions averaged. Therefore, the worst truncation error when averaging 256 samples is 0.0623 LSBs.
______________________________________________________________________________________
21
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
Upper Threshold Register
A conversion result greater than the value stored in the upper threshold register results in a fault, increasing the internal fault counter by one. When the fault count exceeds the value stored in fault bits B7-B4 of the channel configuration register, the channel's alarm bits in the alarm register are set, resulting in an interrupt on INT. The upper threshold register data format must be the same as the input channel. When the input channel is configured for single-ended or differential unipolar voltage measurements, data stored in the upper threshold register is interpreted as straight binary. For input channels configured for temperature measurements or as differential bipolar voltage inputs, the upper threshold register data is interpreted as two's complement. Load the register with FFF hex to disable upper threshold faults in unipolar mode, and 7FF hex in temperature or bipolar mode. The power-up/reset default is FFF hex. See the Command Word section on how to read/write to the upper threshold registers. nel configuration register, the alarm bits for that particular channel are updated to indicate an alarm. When any bit in the alarm register is set, the INT output becomes active, and stays active until all alarm bits are cleared. See the Alarm Register section for more information.
Servicing Interrupts at INT
After detecting an interrupt on INT, the C's interrupt routine should first read the alarm register to find the source of the alarm and reset the alarm bits by using any of the methods described in the Alarm Register section. Then it can continue with any other action required by the application to react to the alarm. Note: Multiple alarm conditions can be present. The INT remains active until all alarm conditions have been cleared.
Performing Conversions
At power-up or after a RESET command, the MAX1253/MAX1254 default to shutdown mode with all channels enabled, set for single-ended voltage measurements, and with the scan mode set to manual. Start a conversion by issuing a manually triggered conversion command with the address bits of the channel selected (see the Manual Conversion section for more details) or by setting automatic scan mode. To place the MAX1253/MAX1254 in automatic scan mode, set scan mode bit B2 in the setup register to logic 1. In automatic scan mode, the MAX1253/MAX1254 convert all enabled channels starting with the internal temperature sensor, followed by the VDD monitor, then by AIN0 to AIN7. As the scan sequence progresses, the analog inputs are converted and the resulting values are stored for each channel into its current data register. Once the scan cycle completes, the MAX1253/ MAX1254 wait a period determined by the sample wait bits (B7, B6, B5) in the setup register and then repeat the scan cycle. After configuring the MAX1253/MAX1254 with automatic scan mode enabled, the devices do not require any intervention from the system C until an alarm is triggered. All conversion and monitoring functions can continue running indefinitely.
Lower Threshold Register
Conversion results lower than the value stored in the lower threshold register increment the internal fault counter. Considerations about channel configuration register fault bits B7-B4, INT interrupts, and data format are the same as for the upper threshold register. Set the register to 000 hex to disable lower threshold faults in unipolar mode, or to 800 hex in temperature or bipolar mode. The power-up/reset default is 000 hex. See the Command Word section on how to read/write to the lower threshold registers.
Current Data Registers
The current data register holds the last conversion result or the digitally averaged result, when enabled (see the Averaging section). The current data registers default to 800 hex at power-up/reset and can be read from and written to through the serial interface. See the Command Word section on how to read/write to the current data registers.
INT Interrupt Output
INT provides an indication that an alarm has occurred in the system. It can be programmed (see Table 9) to operate as a push-pull digital output or as an opendrain output (requiring either a pullup or a pulldown resistor) for wired-OR interrupt lines. Bits B3 and B4 in the setup register configure INT and determine its response to an alarm event. When an internal fault counter exceeds the threshold stored in the fault bits (B7-B4) of the corresponding chan22
Manual Conversion
In manual mode (scan mode bit in the setup register set to zero, the default after power-up/reset), the MAX1253/MAX1254 convert individual channels with the Manually Triggered Conversion command. Assuming that, either by power-up/RESET defaults or by previous initialization, the channel to be addressed is both enabled and configured for the type of signal to be acquired (voltage/temperature, single ended/differ-
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
ential, or unipolar/bipolar), carry out the following steps to execute a manual conversion. See Figure 9 for manual conversion timing: 1) Disable autoscan (set up register scan mode bit to zero), if necessary. 2) Pull CS low. 3) Initiate a conversion by issuing a Manually Triggered Conversion command (0000, followed by the address bits of the channel to be converted). 4) Pull CS high to start the conversion. 5) Maintain a logic high on CS to allow for reference power-up (if the reference mode requires it) and conversion time. 6) Pull CS low. 7) Issue a Read Current Data Register for SelectedChannel command (0010, followed by the same address of the channel in the Manually Triggered Conversion command). VDD value can be calculated from the digitized data with the following equation: V VDD = 2 x (current _ data _ register _ content) x REF 4096 The reference voltage must be larger than 1/2VDD for the operation to work properly. VDD monitoring requires 10.6s (typ) per measurement.
MAX1253/MAX1254
Temperature Measurement
The MAX1253/MAX1254 perform temperature measurement by measuring the voltage across a diode-connected transistor at two different current levels. The following equation illustrates the algorithm used for temperature calculations: q k temperature = (VHIGH - VLOW) x IHigh n x ln ILOW where: VHIGH = sensor-diode voltage with high current flowing (IHIGH) VLOW = sensor-diode voltage with low current flowing (ILOW) q = charge of electron = 1.602 10-19 coulombs k = Boltzman constant = 1.38 10-23 J/K n = ideality factor (slightly greater than 1)
Voltage Measurements
Every voltage measurement (internal VDD or external input channel) requires 10.6s to complete. If the internal reference needs to power up (reference mode = 01), an additional 40s is required every time the MAX1253/MAX1254 come out of automatic shutdown mode after a sample wait period greater than 80s.
Monitoring VDD
This internal acquisition channel samples and converts the supply voltage, VDD.
tPU+CONV
CS
SCLK
DIN
C3
C2
C1 C0
A3 A2 A1
A0
C3
C2
C1 C0
A3
A2 A1
A0
DOUT
Figure 9. Manual Conversion Timing Without Reading Data ______________________________________________________________________________________ 23
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
The temperature measurement process is fully automated in the MAX1253/MAX1254. All steps are sequenced and executed by the MAX1253/MAX1254 each time an input channel (or an input channel pair) configured for temperature measurement is scanned. The resulting 12-bit, two's complement number represents the sensor temperature in degrees Celsius, with 1 LSB = +0.125C. The MAX1253/MAX1254 support both single-ended and differential temperature measurements. the MAX1253/MAX1254 by issuing a command to read a specific channel with the Read Current Data Register for Selected Channel command. Read all current data registers at once with the Read Current Data Registers for All Channels command. For more complex applications, the monitoring and interrupt generation features of the MAX1253/MAX1254 require a second step of initialization. Each enabled channel to be monitored requires configuration using a Write Configuration Register for Selected Channel command. Each command is a 5-byte write that sets the upper and lower fault thresholds, the number of faults for an alarm before an interrupt is generated, and an average algorithm parameter if the application requires input signal filtering. Applications can read the current data registers and respond to interrupts signaled by the INT output (see the Servicing Interrupts at INT section). All the MAX1253/MAX1254 registers can be verified by reading back written data, including the configuration registers. This feature is useful for development and testing (see Table 2).
Applications Information
Setting Up the MAX1253/MAX1254 Subsystem
The MAX1253/MAX1254 are autonomous subsystems, requiring only initialization to scan, convert, and monitor the voltage signals or the temperature sensors connected to their input channels. For simple applications, using any number of the input channels and any combination of voltage/temperature and unipolar/differential, with no interrupt generation required, use the following intitialization procedure: * Issue a Write Global Configuration Registers command. This is a single, 5-byte write operation that configures the input channels, enables the channels to be used, sets the sample wait time between scans, configures the interrupt output INT, selects the reference mode, and starts the automatic scan mode. See the Write Global Configuration Registers Command section, Table 2, and Tables 5-10. Immediately after the global configuration register is loaded, the MAX1253/MAX1254 begin to update the current data registers. Acquire conversion data from
Power-Up/Reset Defaults Summary
Setup Register Power-Up/Reset Defaults At initial power-up or after a RESET command, the setup register resets to 00 hex. Consequently, the MAX1253/MAX1254 are configured as follows: * Sample wait time is 0s. * INT output is open drain and outputs an active-low signal to signify an alarm. * Manual conversion mode. * External reference for voltage measurements.
Table 15. Power-Up/Reset Defaults Summary
REGISTER Setup Channel enable Input configuration Alarm register Channel configuration Upper threshold Lower threshold Current data registers BIT RANGE B0 to B7 B0 to B11 B0 to B11 B0 to B23 B0 to B7 B0 to B9 B0 to B9 B0 to B9 POWER-UP/RESET STATE All 0s All 1s All 0s All 0s All 0s All 1s All 0s 200hex COMMENTS See Setup Register Power-Up/Reset Defaults All channels (int/ext) enabled All single-ended voltage inputs No alarms set Faults = 0, no averaging All upper thresholds max range All lower thresholds min range Set at midrange
24
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Channel-Enable Register Power-Up/Reset Defaults At power-on or after a RESET command, the channelenable register resets to FF hex, enabling all channels: the internal temperature sensor, the VDD monitor, and AIN0-AIN7. Input Configuration Register Power-Up/Reset Defaults At power-on or after a RESET command, the input configuration register resets to 00 hex, configuring AIN0-AIN7 for single-ended voltage measurement. Alarm Register Power-Up/Reset Defaults At power-on or after a RESET command, the alarm register is reset to 000000 hex, indicating that no alarm condition exists. Current Data Register Power-Up/Reset Defaults At power-on or after a RESET command, each channel's current data register is reset to 800 hex. Upper Threshold Register Power-Up/Reset Defaults At power-on or after a RESET command, each channel's upper threshold register is reset to FFF hex. This state effectively disables the upper threshold. Lower Threshold Register Power-Up/Reset Defaults At power-on or after a RESET command, each channel's lower threshold register is reset to 000 hex. This state effectively disables the lower threshold. Channel Configuration Register Power-Up/Reset Defaults At power-on or after a RESET command, each channel's configuration register is reset to 000 hex, which configures the fault bits to cause an alarm to occur on the first overrange or underrange condition and disables averaging. ple wait period (if sample wait time > 80s), and no power-up time in reference mode 10. The sampling period is calculated as follows: tsw = (tpu) + (Nv)tconv[volt] + (Nt)tconv[temp] + twait where: tsw = all channels scan sampling period tpu = reference power-up time tconv[volt] = voltage-configured channel conversion time Nv = number of voltage-configured channels tconv[temp] = temperature-configured channel conversion time Nt = number of temperature-configured channels twait = sample wait time The terms in the above equation are determined as shown above by the number of enabled channels, the input channel configuration (voltage vs. temperature), the sample wait time, and the reference mode. The following calculation shows a numeric example: tsw = 40s + 8 x 10.6s + 2 x 46s + 395s = 611.8s * 40s is the time required for the reference to powerup (reference mode = 00) every time the MAX1253/MAX1254 come out of automatic shutdown mode after a sample wait period. * 8 x 10.6s is the time required for seven channels configured for voltage measurement and the VDD monitor. * 2 x 46s is the time required for temperature measurement (46s for each temperature measurement (internal or external)). * 395s is the sample wait time, set by bits B5, B6, B7 of the setup register (see Tables 7 and 8). The MAX1253/MAX1254 use an internal clock for all conversions. The serial interface clock does not affect conversion time. Performing eight single-ended remote channels temperature measurements, an internal temperature measurement, and an internal VDD measurement with a sample wait time of zero results in an average conversion rate of 24ksps or 2.4ksps per channel. Performing eight single-ended voltage measurements, an internal temperature measurement, and an internal VDD measurement with sample wait time of zero results in an average conversion rate of 70ksps or 7ksps per channel.
MAX1253/MAX1254
Computing Data Throughput
The MAX1253/MAX1254 throughput rate depends on the number of enabled channels, their configuration (temperature or voltage), and the reference mode. Voltage measurements require 10.6s (typ) to complete, and temperature measurements require 46s. Channel pairs configured for differential measurements count as only one for throughput computation. The reference system takes 20s to power up in reference mode 00 prior to each temperature measurement, 40s to power up in reference mode 01 after each sam-
______________________________________________________________________________________
25
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
Automatic Reference Shutdown
The MAX1253/MAX1254 enter an automatic shutdown mode when in reference mode 00 or when the sample wait is greater than 80s in reference mode 01. Using either of these reference modes and a sample wait period as long as the application allows results in the lowest power consumption. Single-Ended Temperature Measurement Connect the anode of a diode-connected transistor to the input channel and the cathode to ground. Choose ground connections for sensors away from high-current return paths to avoid the introduction of errors caused by voltage drops in the board/system ground, which is the main drawback for single-ended measurements. Practical options for better accuracy are the use of a star-configured subsystem ground or a signal ground plane; to isolate the anode sensor connection trace away from board and system noise sources; or to shield it with ground lines and ground planes (when available) to prevent accuracy degradation in the temperature measurements caused by magnetic/electric noise induction. Configure the MAX1253/MAX1254 input used for singleended temperature measurement in the input configuration register (see Tables 9 and 10) and enable the analog input in the channel-enable register (see Table 4).
Temperature Measurement
The MAX1253/MAX1254 support both single-ended and differential temperature measurements. The design decision between the two types of measurements depends on the desired level of accuracy and on type and/or number of temperature sensors. The superior common-mode rejection and lower noise of the differential mode reduces measurement errors and provides higher accuracy, while single-ended measurements require a lower number of connections, resulting in a simpler implementation and a higher number of monitored points for each MAX1253/MAX1254. Differential Temperature Measurement Connect the anode of a diode-connected transistor to the even input channel and the cathode to the odd input channel of an input pair configured for differential temperature measurement (AIN0/AIN1, AIN2/AIN3, AIN4/AIN5, or AIN6/AIN7). Run the two sensor connection lines parallel to each other with minimum spacing. This improves temperature measurement accuracy by minimizing the differential noise between the two lines, since they have equal exposure to most sources of noise. For further improved noise rejection, shield the two sensor connections by running them between ground planes, when available. Configure the MAX1253/MAX1254 inputs for differential temperature measurement in the input configuration register (see Tables 9 and 10) and enable the even channel number in the channel enable register (see Table 4).
Remote Temperature Sensor Selection
Temperature-sensing accuracy depends on having a good-quality, diode-connected, small-signal transistor as a sensor. Accuracy has been experimentally verified for 2N3904-type devices. The transistor must be a small-signal type with low base resistance. Tight specifications for forward current gain (+50 to +150, for example) indicate that the manufacturer has good process controls and that the devices have consistent VBE characteristics. CPU on-board sensors and other ICs' on-board temperature-sensing devices can also be used (see Table 16 for recommended devices).
OUTPUT CODE 11....111 11....110 11....101 FS = VREF ZS = 0 00....011 00....010 00....001 00....000 0 0 1 2 3 INPUT VOLTAGE (LSB) FS = 3/2 LSB FS 1 LSB = VREF 4096 FULL-SCALE TRANSITION
Table 16. Remote Sensor Transistor Manufacturers
MANUFACTURER Central Semiconductor (USA) Fairchild Semiconductors (USA) Motorola (USA) Rohm Semiconductor (Japan) Siemens (Germany) Zetex (England) Diodes Inc. MODEL NUMBER CMPT3904 MMBT3904 MMBT3904 SST3904 SMB3904 FMMT3904CT-ND MMBT3904
Figure 10. Unipolar Transfer Function, Full Scale (FS) = VREF 26 ______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
OUTPUT CODE 011....111 011....110 FS = VREF 2 OUTPUT CODE 011....111 011....110
000....010 000....001 000....000 111....111 111....110 111....101 100....001 100....000
ZS = 0 -V -FS = REF 2 V 1 LSB = REF 4096
000....010 000....001 000....000 111....111 111....110 111....101 100....001 100....000
-FS
0 INPUT VOLTAGE (LSB)
+FS - 1 LSB
-256C
0 TEMPERATURE C
+255.875C
Figure 11. Bipolar Transfer Function, Full Scale (FS) = VREF/2
Figure 12. Temperature Transfer Function
Transfer Function
Figure 10 shows the nominal transfer function for singleended or differential unipolar configured inputs, Figure 11 illustrates the transfer function for differential bipolar conversions, and Figure 12 shows temperature conversions. Code transitions occur halfway between successive-integer LSB values. Output coding is binary, with 1 LSB = 610V (MAX1253) or 1mV (MAX1254) for unipolar and bipolar operation, and 1 LSB = +0.125C (MAX1253/MAX1254) for temperature measurements. For unipolar operation, the 0 code level transition is at [1/2(VREF / 4096)]. The FFF hex level transition is at [4094.5 (VREF / 4096)]. 1 LSB = VREF / 4096.
noisy, connect a 10 resistor in series with the supply to improve power-supply filtering.
Definitions
Integral Nonlinearity
Integral nonlinearity is the deviation of the values on the actual transfer function from a straight line. This straight line can be either a best-straight-line fit or a line drawn between the end points of the transfer function, once offset and gain errors have been corrected. The static linearity parameters for the MAX1253/MAX1254 are measured using the end-point-fit method. INL is specified as the maximum deviation in LSBs.
Differential Nonlinearity (DNL)
Differential nonlinearity is the difference between an actual step width and the ideal value of 1 LSB. A DNL error specification of less than 1 LSB guarantees no missing codes and a monotonic transfer function.
Layout, Grounding, and Bypassing
For best performance, use PC boards. Do not use wirewrap boards. Board layout should ensure that digital and analog signal lines are separated from each other. Do not run analog and digital (especially clock) signals parallel to one another or run digital lines underneath the MAX1253/MAX1254 package. High-frequency noise in the V DD power supply can affect the MAX1253/MAX1254 performance. Bypass the VDD supply with a 0.1F capacitor from VDD to GND, close to the VDD pin. Minimize capacitor lead lengths for best supply-noise rejection. If the power supply is very
Offset Error
The offset error is the difference between the ideal and the actual analog input value at the first transition of the ADC, usually from digital code 0 to code 1 for straight binary output. For the MAX1253/MAX1254, the transition between code 0 and code 1 should occur at an input voltage of 1/2 LSB, or 305V for the MAX1253 and 500V for the MAX1254.
______________________________________________________________________________________
27
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor MAX1253/MAX1254
Gain Error
The gain error is the difference between the ideal and actual value of the analog input difference between the first and last transitions of the ADC output. The first transition is from digital code 0 to code 1, and the last from code (2N-2) to code (2N-1), where N = number of ADC bits for straight binary output code. For the MAX1253/MAX1254, the ideal difference in the input voltage between code transitions 0 to 1 and code transitions 4094 to 4095 is 4094 x LSB. For the MAX1253, this is 2.5V - 2 x LSB = 2.498780V, and for the MAX1254, this is 4.096V - 2 x LSB = 4.094V. Gain error is a DC specification, usually normalized to the FS ideal analog value and given in percent of FSR or ppm. There are other noise sources besides quantization noise, including thermal noise, reference noise, clock jitter, etc. Therefore, SINAD is calculated by taking the ratio of the full-scale signal to the RMS noise, which includes all spectral components minus the fundamental and the first five harmonics.
Total Harmonic Distortion (THD)
Total harmonic distortion (THD) is the ratio of the RMS sum of the first five harmonics of the input signal to the fundamental itself. This is expressed as: THD = 20 x log
(V22
+ V32 + V42 + V52) V1
Signal-to-Noise Ratio
For a waveform perfectly reconstructed from digital samples, signal-to-noise ratio (SNR) is the ratio of the full-scale analog input (RMS value) to the RMS quantization error (residual error). The ideal theoretical minimum analog-to-digital noise is caused by quantization error only, results directly from the ADC's resolution (N bits), and can be calculated with the following equation: SNR = (6.02 x N + 1.76)dB
where V 1 is the fundamental RMS value, and V 2 through V5 are the RMS values of the 2nd- through 5thorder harmonics, respectively.
Power-Supply Rejection
Power-supply rejection is the ratio between the change in the ADC full-scale output to the change in powersupply voltage when the power-supply voltage is varied from its nominal value. It is specified in V/V or V/V.
Signal-to-Noise Plus Distortion
Signal-to-noise plus distortion (SINAD) is the ratio of the fundamental input frequency's RMS amplitude to the RMS equivalent of all other ADC output signals: SINAD (dB) = 20 x log (SignalRMS / NoiseRMS)
28
______________________________________________________________________________________
Stand-Alone, 10-Channel, 12-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Typical Operating Circuit
MAX1253/MAX1254
POWER SUPPLY +V -5V +5V +3V
C
VDD
VREF REFERENCE GLOBAL REGISTERS TEMP SENSOR INT SPI INTERFACE
AIN0 AIN1 48V AIN2 AIN3 AIN4 AIN5 AIN6 AIN7 GND CHANNEL REGISTERS MUX ADC DIGITAL BLOCK
SPI I/F
MAX1253 MAX1254
REMOTE TEMP
Chip Information
TRANSISTOR COUNT: 89,473 PROCESS: 0.6m BiCMOS
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 29 (c) 2003 Maxim Integrated Products Printed USA is a registered trademark of Maxim Integrated Products.